PROBLEM
The Fatigue Analyzer in TestSuite is takes an extremely long time to open test runs for analyzing; over an hour in some cases.
ANSWER
Check the size of the AnalysisDefinition.1.Traits file in the test. If the size is excessive it could cause the analysis run a long time to load (Figure 1). If the user removes this file the test should load normally.
The user will lose the existing analysis runs but should be able to generate new ones.
Figure 1 - AnalysisDefinition.1. file showing excessive size of over 7 GB
Next create a new analysis definition. This is needed when removing the previous definition.
Right-click on the test run and select Analyze Test Run (Figure 2).
Figure 2
Enter a new definition name and click Add New, then click Add Analysis (Figure 3).
Figure 3
Afterwards the user should be able to get at their data (Figure 4).
Figure 4